Our portfolio of digital output flow meters offers a wide range of technologies for precise measurement and control tasks. To help you navigate, here is an overview of the available digital interfaces, each leading to detailed descriptions:
Note: Navigation tiles linking to each section: TTL Output, Hall Sensor (NPN), Reed Sensor, Namur Sensor, NPN Pulse Output, PNP Pulse Output, Transistor/Pulse Output, IO-Link, CAN Bus.
Detailed Overview of DDM Sensors Digital Output Signals
Flow Meters with TTL Output
An output signal based on Transistor-Transistor Logic (TTL) provides defined voltage levels for the logical “High” and “Low” states. This clear signal definition allows direct connection to microcontrollers, frequency counters, and digital logic circuits without needing additional signal converters.
At DDM Sensors, we offer the following flow meters with TTL output:
- VCT Series: Precision turbine flow meters (0.05 to 350 L/min)
- FLT Series: High-pressure turbine flow meters (up to 500 bar)
excl. 19% VAT plus shipping costs
Hose connection Ø: 9,8 to 32mm
Measurement range: 0,1 to 350l/min
Repeatability: ± 0,025 % of reading
Temperature probe media exposed: Type T thermocouple
Datasheet : pdf | 314 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Thread: AN8; AN10; AN12
Measurement ranges: 0,1 to 100l/m
Repeatability: ± 0,025 % of reading
Temperature probe media exposed: Type T thermocouple
Datasheet : pdf | 314 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Thread: AN8 bis AN32; M18 bis M52
Measurement ranges: 0,06 to 1200l/m
Repeatability: ± 0,025 % of reading
Temperature measuring point: Type T thermocouple
Datasheet : pdf | 202 KB
excl. 19% VAT plus shipping costs
Also available is the ASP Smart-Pickoff, a retrofittable sensor pickup that equips existing turbines with a TTL output and integrated parameter memory. All listed models deliver a maximum output frequency of 2 kHz.
Hall Sensor (NPN)
The Hall sensor provides wear-free measurement acquisition, resulting in high durability and robustness. It outputs an NPN signal via an open-collector output switching to ground (GND).
This principle is utilized across our extensive range of oval gear flow meters:
- OG1 (available in stainless steel or PEEK)
- OG2
- OG3
- OG4
- OG5
- OG6
- OG7
These oval gear meters cover flow ranges from 0.01 L/min to 500 L/min and are rated for process pressures up to 700 bar. Furthermore, we equip our FT2 Hall radial turbine for opaque liquids and the NSF-certified NSF Beverage mini paddlewheel sensor with an NPN signal.
excl. 19% VAT plus shipping costs
Connection: 1/4″ BSP F or NPT F
Measurement range: 0,01 … 1,0l/min at 30cst oil; 0,1 … 1,0l/min with water
Repeatability: ±0,1%
Output: Impuls NPN; voltage
Pressure Ranges: <10bar, <50bar, <400bar, <700bar
Temperature range: -20 – 80°C, -40 – 100°C, -40 – 150°C
Data sheet: pdf | 619 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 1/4″ BSP F or NPT F
Measurement range: 0,03 … 4,0l/min at 30cst oil; 0,15 … 4,0l/min with water
Repeatability: ±0,1%
Output: Impuls NPN; voltage
Pressure Ranges: <10bar, <50bar, <400bar, <700bar
Temperature range: -20 – 80°C, -40 – 100°C, -40 – 150°C
Data sheet: pdf | 523 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 1/2″ BSP F or NPT F
Measurement range: 0,05 … 10,0l/min at 30cst oil; 0,5 … 10,0l/min with water
Repeatability: ±0,1%
Output: Impuls NPN; voltage
Pressure Ranges: <10bar, <50bar, <400bar, <700bar
Temperature range: -20 – 80°C, -40 – 100°C, -40 – 150°C
Data sheet: pdf | 1,009 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 3/4″ BSP F or NPT F
Measurement range: 0,25 … 50,0l/min at 30cst oil; 2,5 … 50,0l/min with water
Repeatability: ±0,1%
Output: Impuls NPN; voltage
Pressure Ranges: <10bar, <50bar, <400bar, <700bar
Temperature range: -20 – 80°C, -40 – 100°C, -40 – 150°C
Data sheet: pdf | 613 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 1″ BSP F or NPT F, R21.50, G1-11
Measurement range: 0,5 … 100,0l/min at 30cst oil; 4,0 … 100,0l/min with water
Repeatability: ±0,1%
Output: Impuls NPN; voltage
Pressure Ranges: <10bar, <50bar, <400bar
Temperature range: -20 – 80°C, -40 – 100°C, -40 – 150°C
Data sheet : pdf | 447 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 1 1/2″ BSP F or NPT F
Measurement range: 2 … 200l/min at 30cst Öl; 10 … 200l/min with water
Repeatability: ±0,1%
Output: Impuls NPN; voltage
Pressure Ranges: <10bar, <50bar, <400bar,
Temperature range: -20 – 80°C, -40 – 100°C, -40 – 150°C
Data sheet: pdf | 509 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 2″ BSP F or NPT F
Measurement ranges: 5 … 500l/min at 30cst oil; 20 … 500l/min with water
Wiederholbarkeit: ±0,1%
Output: Impuls NPN; voltage
Pressure Ranges: <50bar
Temperature range: -20 – 80°C, -40 – 100°C, -40 – 150°C
Data sheet: pdf | 533 KB
excl. 19% VAT plus shipping costs
Reed Sensor
A Reed sensor provides a dry, potential-free contact actuated magnetically. This simple and robust technology is ideal for applications requiring volume pulse counting without an external power supply at the sensor. Due to its potential-free design, it can be used in combination with isolating switching amplifiers in explosion-proof (Ex) areas. We offer the pulse/frequency output (Reed contact) as an option for our entire line of oval gear meters, from OG1, OG2, OG3, OG4, OG5, and OG6 to OG7.
Namur Sensor
Namur sensors are two-wire proximity switches complying with the EN 60947-5-6 standard, outputting a current-controlled signal. Their primary purpose is to ensure intrinsic safety in hazardous, explosion-prone areas.
By limiting current and voltage within the signal circuit, the generation of spark energy capable of ignition is prevented. This safety-critical output variant is available for all our heavy-duty stainless steel oval gear series: OG1, OG2, OG3, OG4, OG5, OG6, and OG7.
NPN Pulse Output
The NPN pulse output is an open-collector output switching to ground, providing a frequency proportional to the flow rate. It is an established industrial standard for connecting to digital counters, data acquisition systems, and PLC frequency inputs.
This output signal is available across a broad spectrum of our flow meters, including:
- Paddlewheel Meters: Beverage Meter, FT2 Optical, 800, 900, and 1000 Series
- Ultrasonic Flow Meters: Process Atrato, Atrato, MetraFlow (2x NPN)
- All Oval Gear Meters
Additionally, our portfolio features the Pulsite Link converter, which converts standard flow meter pulse outputs into linearized analog and NPN/PNP outputs.
PNP Pulse Output
The PNP pulse output, also known as a “sourcing” output, switches the signal to the positive supply potential (+V). As with the NPN output, the emitted frequency is directly proportional to the flow rate. This output type is a widely adopted standard in European automation engineering and is natively supported by many PLC digital input cards. We provide PNP pulse outputs on the 800, 900, and 1000 turbine series, the Process Atrato, Atrato, and MetraFlow (1x PNP) ultrasonic sensors, the Pulsite Link converter, and optionally on all oval gear meters.
excl. 19% VAT plus shipping costs
Connection: 3/8” John Guest, 1/2” BSP, 1/2” NPT
Measurement range: 2 … 500ml/min to 0,1 … 20l/min
Repeatability: ±0.1% (25 to 100% v.MB); ±0.5% (< 25 v.MB)
Material of wetted parts: PEEK / 316 ; PEEK / Borosilikatglas
Output: Impuls (NPN or PNP); 4 – 20mA; 0 – 10V; 0 -5V; Display
Temperature range: -10 – 60°C, -10 – 110°C
Data sheet: pdf | 1 MB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: ¼” BSP
Measurement range: 2 … 500ml/min to 0,1 … 15l/min
Repeatability: ±0.1% +0.005% FSD
Material of wetted parts: 316 and PEEK
Output: Impuls (NPN or PNP);
Data sheet: pdf | 372 KB
Manuel: pdf | 2 MB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 1/8” & 1/4″ hose
Measurement ranges: 20 … 1000 ml/min & 100 … 5000 ml/min
Repeatability: ±0.1% plus ±0.02% FSD
Material of wetted parts: PFA hose with FDA approval
Output: Impuls (NPN or PNP); 4 – 20mA; 0 – 10V; 0 -5V; Display
Temperature range: -10 – 60°C
Data sheet: pdf | 1,003 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Hose connection Ø: 8 & 12mm
Measurement range: 0,05… 0,5 l/min to 0,50 … 15,0 l/min
Repeatability: 0,1%
Material of wetted parts: PVDF including NSF, customer-specific
Output: Impuls (NPN or PNP)
Temperature range: -25 … 60°C or -25 … 125°C
Data sheet: pdf | 406 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 1/4″ BSPF, 1/4″ NPTF
Measurement range: 0,05… 0,5 l/min to 0,50 … 15,0 l/min
Repeatability: 0,1%
Material of wetted parts: PVDF or stainless steel
Output: Impuls (NPN or PNP)
Temperature range: -25 … 60°C or -25 … 125°C
Data sheet: pdf | 348 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 1/2″ BSPF
Measurement range: 0,05… 0,5 l/min to 2,0 … 30,0 l/min
Repeatability: 0,1%
Material of wetted partsin contact with media: PVDF or stainless steel
Output: Impuls (NPN or PNP)
Temperature range: -25 … 60°C or -25 … 125°C
Data sheet: pdf | 366 KB
excl. 19% VAT plus shipping costs
Transistor / Pulse Output
A flexible transistor or pulse output is characterized by its configurability, particularly regarding the pulse rate (pulses per unit volume). This adaptability makes it a versatile solution for precise batching and dosing tasks, where pulse weightings must match the downstream PLC input specifications exactly.
The battery-powered Pulsite Solo display unit features an optional scaled transistor output. The electromagnetic flow meter JUMO flowTRANS MAG H20 also includes a digital transistor/pulse output alongside modern interfaces like IO-Link.
excl. 19% VAT plus shipping costs
Measurement principle: Magnetic-inductive flow measurement (MID)
Nominal diameters: DN15 to DN25
Measurement range: 0.05 to 35 l/min (DN15) | 0.1 to 75 l/min (DN20) | 0.2 to 150 l/min (DN25)
Measurement accuracy: ±0.5% of the measured value
Repeatability: ±0.2%
Display: Integrated HMI display for showing process values
Outputs: 4 to 20 mA | 0 to 10 V | Pulse/frequency output | IO-Link
Electrical connection: M12 connector
Data Sheet: pdf | 1 MB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Linearisation: Calibration points of the flow meter can be stored
Signal input: Pulse or Reed switch
Response time: from 100ms
Flow alarm outputs: programmable high and low alarms
Operating temperature range: 0 – 65°C
Protection class: IP64
Data sheet Pulsit Link: pdf | 490 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
LCD display: current flow rate & total flow rate
Possible units: Gal – cc – kg – gms – Ltr & sec – min – Hr
Power supply: 5 to 24Vdc or AA battery
Protection class: IP64
Data sheet Pulsit solo: pdf | 1,005 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Hose connection Ø: 3/8“
Measurement range: 0,6 – 10 l/min
Repeatability: 0,1%
Material of wetted parts: PVDF including NSF
Output: Impuls (NPN or PNP)
Temperature range: 0 to 70°C°C
Data sheet: pdf | 200 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 8mm & 13mm hose; ¼“ up to 1“ BSP
Measurement range: 0,02 l/min up to 160,0 l/min
Repeatability: 0,1%
Material of wetted parts : PVDF, PVC, Brass or Stainless Steel
Output: Impuls
Temperature Range : -10 to 80°C
Data sheet FT2 optical: pdf | 238 KB
excl. 19% VAT plus shipping costs
excl. 19% VAT plus shipping costs
Connection: 8mm & 13mm hose; ¼“ up to 1“ BSP
Measurement range: 0,5 l/min to 160,0 l/min
Repeatability: 0,1%
Material of wetted parts : PVDF, PVC, Brass or Stainless Steel
Output: Impuls
Temperature range : -15 up to 125°C
Data sheet FT2 hall effect: pdf | 245 KB
excl. 19% VAT plus shipping costs
IO-Link
IO-Link is a standardized, intelligent point-to-point communication protocol according to IEC 61131-9, enabling bidirectional data exchange between the sensor and control level. Beyond transmitting real-time process values, this interface allows remote parameterization, retrieval of detailed diagnostic data, and event reporting (e.g., threshold limit alerts).
We implement this technology in our JUMO flowTRANS MAG H20 and JUMO flowTRANS US W02 flow meters. The MAG H20 also features Bluetooth and NFC interfaces for effortless app-based configuration.
CAN Bus
The CAN bus (Controller Area Network) is a serial, real-time communication bus system compliant with ISO 11898. Differential two-wire transmission makes the signal highly immune to electromagnetic interference. Because multiple nodes communicate over a single shared line, wiring complexity is significantly reduced.
With the VCA-CAN flow computer, we provide a digital CAN bus signal conforming to the CAN 2.0B (High Speed) standard. The VCA-CAN can be combined with both our turbine flow meters and our oval gear flow meters.
excl. 19% VAT plus shipping costs
Input signals: 2.5 kHz TTL max.
Accuracy: ± 0,1 %
Operating temperature range: −40 °C to+125 °C
Output: CAN-BUS 2.0B high speed (ISO 11989-2:2016)
Data sheet: pdf | 237 KB
excl. 19% VAT plus shipping costs
Advantages of Digital Flow Meters from DDM Sensors
Digital flow meters from DDM Sensors deliver decisive advantages for modern industrial automation:
- High Noise Immunity: Digital signal processing guarantees high noise immunity and excellent signal quality, ensuring precise, loss-free data transmission from the sensor to the controller. This greatly simplifies integration into PLC and IIoT architectures.
- Diagnostics & Parameterization: Advanced interfaces like IO-Link unlock extended diagnostic and remote parameterization capabilities directly in the field or from a central control room.
Performance Features of DDM Sensors Flow Meters
Our digital output flow meters deliver high performance across three core areas:
- Media Compatibility: Utilizing wetted materials such as stainless steel (316L), PEEK, PVDF, and PPS, our sensors handle water, oils, coolants, chemically aggressive fluids, and high-purity media. Dedicated designs, such as our oval gear meters, are optimized for viscous liquids.
- Measuring Ranges: Featuring scalable measuring principles, our portfolio covers the full spectrum from micro-flows as low as 0.002 L/min (Atrato ultrasonic sensor) up to high flow rates of 1200 L/min (FLT high-pressure turbine).
- Accuracy: Offering repeatabilities down to ±0.025% (e.g., VCT series) and measuring accuracies up to ±0.5% of reading (e.g., OG4 series), our devices guarantee reliable, highly accurate data acquisition for critical industrial processes.
Application Areas for DDM Sensors Flow Meters
In machine and plant engineering, DDM Sensors flow meters monitor cooling and lubrication circuits. In water treatment and distribution, they ensure precise volumetric metering. The high chemical resistance of many models makes them the preferred choice for process engineering and the chemical industry. In dosing and filling systems, their accuracy and repeatability safeguard product quality. Furthermore, our precision sensors are widely integrated into test benches and quality assurance setups where reliable test metrics are essential.
Selecting the Right Flow Meter for Your Application
To ensure you receive the most effective and cost-efficient solution for your specific application, contact our technical specialists to discuss measuring ranges, electrical interfaces, or explore our custom flow meters to find the ideal sensor series for your project.